This advertorial for BMG Labtech appeared in DDW Volume 26 – Issue 1, Winter 2024/25 Read the digital issue

Next generation sequencing (NGS) is driving advances in the life sciences including the detection of disease-causing mutations. However, the downstream quantification of nucleic acids and purity assessment remain vital for success. Here we look at ways to ensure fast high-quality results.

NGS requires nucleic acid quantification

Next generation sequencing (NGS) has increased the scale and throughput of work with nucleic acids1. The importance of increasing throughput in sample preparation— especially DNA and RNA quantification—is therefore also growing which is relevant to all research areas where sequencing is needed. For example, the sequencing of genomic DNA (gDNA), cDNA, total RNA, mRNA, and the use of techniques like chromatin immunoprecipitation sequencing (ChIP-seq) all require quantification of nucleic acids. 

One of the crucial areas where nucleic acid quantification is needed is library preparation which is an essential part of the overall workflow for NGS. Sequencing libraries are typically made by generating fragmented DNA and ligating specialised adapters to both ends of the fragments. Fragments can then be amplified and purified. Nucleic acids need to be quantified, and amounts adjusted to achieve optimal fragmentation. In addition, accurate DNA quantification is essential when pooling different libraries. In some cases, multiple libraries are pooled together and sequenced in the same run to save on resources. 

Which methods are available for nucleic acid quantification?

Fluorescence-based methods are the preferred method for the quantification of nucleic acids for sample preparation and quality control in NGS. The high absorbance of nucleic acids at 260 nm means that absorbance measurements can also be used for their quantification, but fluorescence dyes that intercalate into nucleic acid strands between nucleotides generate high fluorescence signals upon binding and enable the detection of nucleic acids with even greater sensitivity and specificity. In this respect, QubitTM represents the gold standard for nucleic acid quantification for NGS purposes. However, other options are available and the Quant-iTTM PicogreenTM dsDNA Assay Kit or AccuBlue® NextGen dsDNA Quantitation Kit are based on the same principle.

""
Figure 1: Comparison of dsDNA quantification methods analyzed on the VANTAstar®. Lowest detection limit was calculated based on measurements shown here. Upper detection limit was taken from kit specification (fluorescent dyes) and reader specification (absorbance).

In the application note “DNA quantification using absorbance and fluorescence measurements”2 BMG LABTECH compared some of the frequently used nucleic acid quantification methods using fluorescence intensity and absorbance (Fig.1). The commonly used methods for nucleic acid quantification were shown to measure DNA accurately at a wide range of concentrations, for different sample volumes, and at different throughputs. Absorbance-based detection quantifies high concentrations of nucleic acids well, but the fluorescence-based methods cover the whole detection range with higher sensitivity and offer greater specificity for nucleic acids since the fluorescent dyes used bind specifically to DNA or RNA. The data shown in figure 1 was detected with a VANTAstar®. However, BMG LABTECH offers a wide range of single- to multi-mode microplate readers for nucleic acid quantification covering the different detection modes. The multi-mode readers FLUOstar® Omega, VANTAstar®, CLARIOstar® Plus and PHERAstar® FSX enable users to select freely between absorbance- and fluorescence-based measurements with high sensitivity and high-throughput.

Quantification of double-stranded DNA can be readily performed with fluorescence measurements on hundreds of samples in parallel. For automatic analysis of nucleic acids, BMG LABTECH’s MARS software comes complete with predefined templates that are accessible with a few clicks. In the same run, fluorescence assay coverage of large nucleic acid concentration ranges is possible through the Enhanced Dynamic Range feature. The use of Linear Variable Filter (LVF) monochromators offers full flexibility for upcoming assays that may require new fluorophores.

The need for purity

The amount of DNA or RNA is not the only important criterion for the successful preparation of samples for NGS. The determination of sample purity is also crucial since impurities may impact the successful completion of subsequent steps in the sequencing process. Absorbance measurements deliver clearcut advantages here since they allow the detection of multiple wavelengths for all-round DNA quality assessment. In the application note “DNA purity ratio – fast and easy absorbance-based evaluation of nucleic acid quality”3, absorbance measurements were made at multiple wavelengths to assess DNA quality. Likely contaminants from sample extraction steps, like salts, phenol, proteins, or particulate substances, were demonstrated as expected to alter the absorbance at 230, 260, 280, or 340 nm, respectively, which distorted the spectra (Fig. 2). Sample quality could be readily and quickly assessed by calculating DNA purity ratios at 260/280 and 260/230 nm. BMG LABTECH’s microplate readers can measure several wavelengths in quick succession using an ultra-fast spectrometer to acquire full spectra from 220-1000 nm in less than 1 sec/well. The acquisition of the whole spectrum enables you to obtain information on purity and quantity from the same measurement without additional expenditure of time.

""
Figure 2: Absorbance spectra of pure and contaminated DNA samples (blank corrected) on the CLARIOstarPlus.

Increasing throughput with microplate readers

Recent advances in sequencing technologies save time and are reducing overall costs. By integrating microplate readers for nucleic acid quantification and purity assessment into automated workflows, operating times can be reduced even further. The available quantification methods for nucleic acids can easily be transferred to higher throughput by using a microplate reader and 96-, 384- or even 1536-well plates instead of classical photometers or fluorometers that can hold only one sample at a time. These rapid and accurate miniaturised formats significantly reduce the amounts of sample reagents needed and increase throughput.

Readers interested in learning more about nucleic acid quantification can consult the BMG Labtech blogs https://www.bmglabtech.com/en/blog/dna-quantification/ and https://www.bmglabtech.com/en/blog/next-generation-sequencing-why-quantifying-exact-dna-rna-is-important/